Phase-A-Matic Rotary Phase Converter 10 Horse Power R-40
Product Description
Phase-A-Matic Rotary Converter 10 Horse Power R-40
-
Instruction Sheet
Important: The Rotary Phase Converter is a FULL POWER converter. However, different load types dictate special sizing requirements. The chart below follows a standard load type as the Largest Motor HP to be applied. The standard load type requires sizing the converter 50% larger than the HP rating of the machine/motor. There are other load types that require sizing the converter twice as large, and some extreme load types require sizing the converter three times larger. See these load types on the Rotary Converter
Important: The Rotary Phase Converter is a FULL POWER converter. However, different load types dictate special sizing requirements. The chart below follows a standard load type as the Largest Motor HP to be applied. The standard load type requires sizing the converter 50% larger than the HP rating of the machine/motor. There are other load types that require sizing the converter twice as large, and some extreme load types require sizing the converter three times larger. See these load types on the Rotary Converter
-
1 Almost all machines require sizing the converter 50% larger or more than the largest HP motor of your machine.
Larger horsepower phase converter systems may be obtained by connecting multiple Rotary Converters in parallel. This is necessary for models that are larger than 100 hp. - 2 HP shown in chart reflects maximum HP allowable under specific conditions. Example: Multiple machinery, not started at the same time, and that is running lightly loaded. For larger sizes consult factory.
- 3 Single-phase supply shown is for absolute maximum output of the Rotary Converter. Most of the time the converter is oversized to provide the high starting current for the motor. It is not always necessary to size the single-phase breakers this large. Contact Phase-A-Matic™ for smaller single-phase breaker qualifications.